Opens in a new tab

Director Tower · Single Platform

18′ Director Tower

The DT18 gives a director a stable, elevated 10′ × 5′ platform at 18′: enough height to read the whole field. A built-in ladder runs inside a caged surround with a locking gate at the base, so the tower secures itself between rehearsals.

The frame is structural steel on 4″ square tubing, cross-braced above 7′ to deter climbing, with expanded metal decking and a metal gable roof. It leaves the Edinburg factory fully assembled and is crane-set on site.

Key Specifications
26'
Total Height
18'
Deck Height
10' × 5'
Platform Size

Full Specifications

Complete Specifications

SKU
DT18
Total Height
26'
Overall footprint
Approximately 7½' × 10' × 26'
Deck Dimensions
10' × 5' (single platform)
Deck Heights
18'
Construction
Structural steel with cross-braced construction, braced above 7' to deter unauthorized climbing. Fabricated at our Edinburg facility, then delivered fully assembled and crane-set.
Frame Material
Structural steel 4" square tubing and angle iron · 4" × 4" × 3/16" legs
Decking Material
Expanded metal diamond grill carbon steel grating
Bracing
Cross-braced construction, braced above 7' against unauthorized entry
Roof Option
Metal gable roof
Access Type
Built-in ladder within a caged surround, with a locking gate at the base
Safety Features
6' tall safety chain on the upper level.
Security Features
Lockable, padlock-ready gate at the foot of the ladder. Frame cross-braced above 7' to deter climbing.
Music Desks
One built-in music reader desk at 22'
Finish & Coating
Frame primed with red oxide primer and painted with a standard marine black enamel. Optional custom colors available. Hot-dip galvanizing is an option.
Orientation
Length toward sideline
Warranty
One year against defects in materials or workmanship. Excludes normal weathering, maintenance, and the wear and tear of normal use.

Site & Installation

Preparing Your Site

What your facilities team, contractor or engineer needs to know before the foundation is poured.

Concrete Base

10’6″ × 16′ × 6″ slab with 30″ deep perimeter and interior beams, subject to ESP’s PE approval.

Soil Bearing

3000# minimum, unless otherwise approved

Anchoring

Legs are welded to inserts set in the foundation as specified in drawings. Rebar grid as specified in drawings.

Installation

Transported fully assembled and set by crane with an experienced operator, followed by a final vendor inspection. Full install option available.

Site Requirements

Requires a flat, grassy area easily accessible by truck and heavy equipment. Delivery under power lines requires 14′ of height clearance. Abnormal soil conditions or limited access may change the quote. City permits and fees are not included.

Engineered Drawings

Engineered stamped drawings optional

What to Expect

From Order to Installation

How a Melhart tower gets from a purchase order to a finished installation on your field.
    You send a purchase order.
    Melhart sends you the submittal package, if you requested it on the PO.
    Once the submittal is approved and any permitting is in place, fabrication begins.
    If you are installing the foundation, an installation package ships to the site ahead of the tower.
    Your team pours the concrete pad, or Melhart pours it if you add the foundation to your order.
    Melhart transports the tower to your site, fully assembled.
    A contracted crane and experienced operator set the tower. Installation is completed and a final vendor inspection is performed.

Ships Ahead of the Tower

Inserts for the legs, plus drawings and photo instructions for the forms, sent in advance when your team pours the foundation.

What You Provide

  • Adequate ingress and egress for delivery and installation
  • Final grading and seeding
  • Scheduling any associated inspections
  • Applicable sales and use tax
  • Any expense beyond normal ingress or egress for installation equipment

Build It Your Way

Customization Options

Custom Finishes & School Colors

Standard red oxide primer with a marine black enamel, or custom school colors matched to your program. Hot-dip galvanizing is available to protect steel in coastal environments.

Engineering & Permitting

Optional engineer-stamped drawings and full submittal packages to support local permitting and PE approval, sent for sign-off before fabrication begins.

Foundation Package

Melhart can add the foundation to your project. If your team pours the pad instead, we ship the installation package ahead of delivery so the foundation is set to spec.

Start Your Quote

Interested in this Model?

Your quote request comes in pre-tagged with this exact model, so our team can price your build without the back-and-forth. Tell us about your program and site, and we’ll follow up with next steps.

DT18
Quoting: 18′ Director Tower
Model Interest

Keep Exploring

Related Towers

Screenshot
SKU: QDSWT8162432

Quad Deck Band Tower

Four observation decks on a single enclosed structure.

SKU: MEDBT1628

Extended Deck Balcony Tower

Total Height
36'
Deck Heights
16' and 28'
Deck Size
4'3" × 12'4"

36′ with metal roof, 32′ without · two 4’3″ x 12’4″ extended balcony decks at 16′ and 28′ · built-in music desks at both levels.

SKU: DTSWEB1624

Balcony Director Tower

Deck Heights
16' and 28'
Deck Size
12' × 4'

Two 12′ x 4′ decks at 16′ and 28′ · enclosed stairwell with locking gate · music reader desk at each level.

Before You Order

About the galvanized finish

Our galvanized tower option is not considered a color or aesthetic finish. Galvanizing is a protective coating applied to steel to prevent corrosion and provide long-term durability in all weather conditions. Because of the nature of the galvanizing process and exposure to environmental elements, discoloration, shade variation, and surface appearance differences are normal and expected. These visual variations do not affect the structural integrity or performance of the tower.

All galvanizing services for our band towers are outsourced to certified third-party galvanizing facilities. As a result, we do not have control over the final appearance of the galvanized finish. By selecting a galvanized tower, the customer acknowledges and accepts the above conditions regarding coating characteristics and potential discoloration.

About the quote

The quoted price is estimated for a flat, grassy area easily accessible by truck or heavy equipment. Abnormal soil conditions revealed by site visit or further investigative soil testing may alter this price, as well as limited accessibility, which may require different installation equipment. Melhart cannot install towers in extreme or hazardous conditions.

Melhart is not responsible for any damage to grass and recommends planning equipment paths prior to arrival, including turning off any sprinklers in the area 48 hours in advance. Delivery under power lines requires 14 ft. height clearance. Does not include any city permits or fees.